This is an old revision of the document!
New documentation for FAQ https://www.nextnano.com/manual/faq/index.html
You can switch between these options using:
Tools ==> Options ==> View ==> Output folder browser
List view
is the default.
Tree view
is convenient if you do a voltage sweep with nextnano++ as for each voltage, one has a different output folder labeled sweep_001/
, or if your simulation output folders are randomly distributed over your hard disk.
The following screenshots highlight the differences.
List view
(default)
Tree view
Sure!
The material parameters are contained in ASCII text files. You can find them in the installation folder:
nextnano³ software:
C:\Program Files (x86)\nextnano\2015_08_19\nextnano++\Syntax\database_nnp.in
nextnano++ software:
C:\Program Files (x86)\nextnano\2015_08_19\nextnano3\Syntax\database_nn3.in
These files can be edited with any text editor such as notepad++ (available free of charge).
More information on how to add materials to the
It is best if you search for a material such as GaSb
and then simply use Copy & Paste
to reproduce all relevant entries and then you rename GaSb
to something like GaSb_test
.
Finally, you adjust the necessary material parameters that you need.
In most cases, you don't have to replace all material parameters.
It is only necessary to replace the ones that you need in the simulation.
It is a good idea to save the new database to a new location such as
C:\Users\<user name>\Documents\nextnano\My Database\database_nnp_GaSb_modified.in
You can then read in the new nextnano++ (or nextnano³) database specifying the location within nextnanomat.
Tools
⇒ Options…
⇒ Material database
⇒ nextnano++ database file:
Tools
⇒ Options…
⇒ Material database
⇒ nextnano³ database file:
A quicker way is the following.
You can overwrite certain material parameters in the input file rather than entirely defining new materials.
For instance if you need HfO2
, you could use the material SiO2
and just change the static dielectric constant and conduction and valence band edges or any other relevant parameters that you need.
So basically, you are using the material SiO2
a modified static dielectric constant and band edges.
More information on how to add materials to the
Please note that we treat all materials to be either of the crystal structure
The short answer is:
Some numerical routines are parallelized which is done automatically. These are the numerical routines, e.g. for calculating the eigenvalues with a LAPACK solver (which itself uses BLAS).
The long answer is:
The nextnano software includes the Intel® Math Kernel Library (MKL).
MKL includes the BLAS and LAPACK library routines for numerical operations.
The MKL dynamically changes the number of threads.
number-of-parallel-threads = 4
has an effect. The NEGF keyword also supports number-of-MKL-threads = 4
(0
means dynamic with is recommended) and MKL-set-dynamic = yes
/ no
.The NEGF algorithms (nextnano.QCL, nextnano.MSB, CBR) include matrix-matrix operations which are well parallelized within the BLAS routines.
If e.g. 4 nextnano simulations are running in parallel on a quad-core CPU, i.e. 4 nextnano executables are running simultaneously and each of them is using calls to the parallelized MKL library simultaneously, the total performance might be slower compared to running these simulations one after the other. In this case using a nextnano executable compiled with the serial version of the Intel MKL could be faster.
In fact, it strongly depends on your nextnano application (e.g. 1D vs. 3D simulation, LAPACK vs. ARPACK eigenvalue solver, …) if you benefit from parallelization or not. In general, the best parallelization can be obtained if you run several nextnano simulations in parallel. For instance, you could do parameter sweeps (e.g. sweep over quantum well width) using nextnanomat's Template feature, i.e. if you run 4 simulations simultaneously on a quad-core CPU, e.g. for 4 different quantum well widths.
In the literature, there are two different notations used:
They are equivalent and can be converted into each other.
Some authors only use 3 parameters $L$, $M$, $N$ (or $\gamma_1$, $\gamma_2$, $\gamma_3$) which is fine for bulk semiconductors without magnetic field but not for heterostructures because the latter require 4 parameters, i.e. $N^+$, $N^-$ (instead of $N$ only) or $\kappa$. If these parameters are not known, they can be approximated.
There are different $\bf{k} \cdot \bf{p}$ parameters for
The 8-band $\bf{k} \cdot \bf{p}$ parameters can be calculated from the 6-band parameters taking into account the temperature dependent band gap $E_{\rm gap}$ and the Kane parameter $E_{\rm P}$ (zinc blende). For wurtzite the parameters are $E_{\rm gap}$ and the Kane parameters $E_{{\rm P}1}$, $E_{{\rm P}2}$.
The 8-band Hamiltonian also needs the conduction band mass parameter $S$ (zinc blende) or $S_1$, $S_2$ (wurtzite). They can be calculated from the conduction band effective mass $m_{\rm c}$, the band gap $E_{\rm gap}$, the spin-orbit split-off energy $\Delta_{\rm so}$ and the Kane parameter $E_{\rm P}$ (zinc blende). For wurtzite the parameters are $m_{{\rm c},\parallel}$, $m_{{\rm c},\perp}$, $E_{\rm gap}$, $\Delta_{\rm so}$, the crystal-field split-off energy $\Delta_{\rm cr}$ and the Kane parameters $E_{{\rm P}1}$, $E_{{\rm P}2}$.
Finally there is the inversion asymmetry parameter $B$ for zinc blende. For wurtzite there are $B_1$, $B_2$, $B_3$.
For more details on these equations, please refer to Section 3.1 The multi-band $\bf{k} \cdot \bf{p}$ Schrödinger equation in the PhD thesis of S. Birner.
Some people rescale the 8-band $\bf{k} \cdot \bf{p}$ in order to avoid spurious solutions. The 8-band $\bf{k} \cdot \bf{p}$ parameters can be calculated from the 6-band parameters taking into account the band gap $E_{\rm gap}$, the spin-orbit split-off energy $\Delta_{\rm so}$ and the Kane parameter $E_{\rm P}$ (zinc blende). For wurtzite the parameters are $E_{\rm gap}$, the spin-orbit split-off energy $\Delta_{\rm so}$, the crystal-field split-off energy $\Delta_{\rm cr}$ and the Kane parameters $E_{{\rm P}1}$, $E_{{\rm P}2}$.
For more details, please refer to Section 3.2 Spurious solutions in the PhD thesis of S. Birner.
See section kp_8band{}
in quantum{}.
You can cite any of the following papers:
For simulations including electrolytes, you should cite:
For simulations that use the Contact Block Reduction method (CBR) (ballistic transport), you should cite any of the following papers:
nextnano.MSB software: For simulations that use the multi-scattering Büttiker (MSB) probe model (NEGF), you should cite:
nextnano.QCLsoftware: For simulations that use the NEGF method, you should cite:
For simulations that use the NEGF algorithm included in the nextnano³ software, you should cite any of these publications:
There might be further papers in the literature that are more suited to be cited in certain cases.