Recombination groups in database{ …_zb{} } and database{ …_wz{} }
There are about 23 identical groups available directly under all zincblende- and wurtzite-related groups. In this section we describe one of them, specifically the group related to recombination models recombination{}.
database{ …{ recombination{} } }
This section specifies the coefficients related to recombination processes. These are used when the current equation is solved. In nextnano++, the following recombination processes are included:
Example
binary_zb {
name = Si # material name, e.g. Si, GaAs, InP, ...
...
recombination{
# Shockley-Read-Hall recombination
SRH{ tau_n = 1.0e-9 # [s] zero doping scattering time for electrons
nref_n = 1.0e19 # [cm^-3] reference doping concentration for electrons
tau_p = 1.0e-9 # [s] zero doping scattering time for holes
nref_p = 1.0e18 # [cm^-3] reference doping concentration for holes
}
# Auger recombination
Auger{ c_n = 2.8e-31 # [cm^6/s]
c_p = 9.9e-31 # [cm^6/s]
}
# direct recombination
radiative{ c = = 2.0e-10 } # [cm^3/s]
# 2.0e-10 for GaAs, 0 for Si (indirect semiconductor)
}
}
Shockley-Read-Hall (SRH) recombination
- tau_n
zero doping scattering time for electrons \(\tau_{n0}\) in the formula (2.8.1.1).
- type:
double
- unit:
s
- nref_n
reference doping concentration for electrons \(N_{n,ref}\) in the formula (2.8.1.1).
- type:
double
- unit:
cm-3
- tau_p
zero doping scattering time for holes \(\tau_{p0}\) in the formula (2.8.1.1).
- type:
double
- unit:
s
- nref_p
reference doping concentration for holes and \(N_{p,ref}\) in the formula (2.8.1.1).
- type:
double
- unit:
cm-3
Auger recombination
Radiative recombination
- c
a coefficient \(C\) in the formula (2.8.2.1).
- type:
double
- unit:
cm3 s-1
- example:
2.0e-10 (for GaAs), 0.0 (for Si, indirect semiconductor)
- c_absorption
If
c_absorption > c, thenc_absorptionwill be used instead ofcas \(C\) to compute absorption coefficients in semiclassical optics. This can be used to enable and control absorption for indirect bandgap materials wherecpractically vanishes. Ideally, for these materials,c_absorptionshould be set in the database to values which reproduce the experimentally observed absorption coefficients.
- type:
double
- unit:
cm3 s-1
- default:
1e-11
Last update: 2025-11-07